Leave a Message
We will call you back soon!
Your message must be between 20-3,000 characters!
Please check your E-mail!
More information facilitates better communication.
Submitted successfully!
We will call you back soon!
Leave a Message
We will call you back soon!
Your message must be between 20-3,000 characters!
Please check your E-mail!
Place of Origin: | china |
---|---|
Brand Name: | Redy-Med |
Certification: | CE/ISO13485 |
Model Number: | S2EY30-113 |
Minimum Order Quantity: | 1pc |
Price: | Negotiation |
Packaging Details: | 1pc pack into a PE bag |
Delivery Time: | 3-7days |
Payment Terms: | T/T, Western Union;Paypal |
Supply Ability: | 15000pcs/month |
Catalog: | SPO2 | Brand Compatible: | New Dixtal |
---|---|---|---|
Length: | 300cm | Cable Material: | TPU |
Patient Size: | Neonate | Sensor: | Y Wrap, Multifuctional |
Highlight: | 300cm Blood Oxygen Sensor,TPU Pulse Oximeter Sensor,TPU Blood Oxygen Probe |
300cm Spo2 Blood Oxygen Sensor Grey Connector Compatible For Dixtal
Compatible For Dixtal New Model Spo2 Sensor Neonata Y Wrap Grey Connector
Technical Specifications:
Connector Color |
Gray |
---|---|
Cable Diameter |
4 mm |
Cable Material |
TPU Jacket |
Category |
SpO2 |
Certifications |
CE, ISO13485 |
Connector Distal |
7pin connector |
Connector Proximal |
Nonate Y wrap |
Latex-free |
Yes |
Packaging Type |
Bag |
Packaging Unit |
1 |
Patient Size |
Adult (>40Kgs)&Neonate(<3kgs) |
SpO2 Technology |
Dixtal |
Sterile |
No |
Total Cable Length |
10 ft/ 3M |
Warranty |
12 months |
Weight |
0.3lb |
I. Product Overview:
Product name: reusable blood oxygen probe
Product Specifications: Adult finger clip, adult finger cover, child finger cover, Child finger cover, Newborn strap.
Main structure: consists of plug, light-emitting tube, receiving tube, cable and bonding parts
Product model: For details, see the label
II. Technical parameters
1) Blood oxygen measurement range: 70%-100%
2) Measurement range of pulse rate: 30-250bpm
3) X-ray resolution: blood oxygen saturation was ±1%; The pulse rate was ±1 BPM
4) X-ray measurement accuracy: 90% ~ 100% blood oxygen saturation is ±2%, 70% ~ 89% ±3%, no requirement below 70%;
Pulse rate of 30bm-59bpm was ±1bpm. 60 BPM - 149 BPM is plus or minus 2 BPM; 150 BPM - 250 BPM is plus or minus 3 BPM
5) The wavelength of the light-emitting tube is 660nm/905nm
There should be no light obstacles such as tape in the place where the light path passes, otherwise it may cause inaccurate measurement of
oxygen saturation and pulse rate. High ambient light can affect measurement, including fluorescent lamps, double ruby lamps, infrared heaters, direct sunlight, etc.
6) Max. optical output power: 2.0MW
7) Compatibility: The Main NPB-600X brand
III . Advantages:
1.) High quality
2.). Short lead time
3.). Competitive price
4.). Professional service
Ⅳ. Delivery details:
1.) Shipping Methods:
a). If order is not very big, we will send you by UPS, DHL, FEDEX, or TNT. Tracking number will be advised after delivery, all of express lead time
is about 3-5 working days.
b). If order is big, we will advise you use Air Freight or Sea freight.
Ⅵ. FAQ: